Off-Grid DC Power Calculators

Choose a calculator to size a DC cable, check battery runtime, match solar panels to an MPPT controller, or verify inverter, BMS and fuse limits.

Core DC System Calculators (8)

DC Wire Size & Voltage Drop Calculator

Size 12V, 24V and 48V copper wire in AWG and mm² from round-trip voltage drop, 75 °C resistance and Blue Sea VI-A derated ampacity.

Open calculator

Battery Runtime Calculator (12V, 24V & 48V)

Calculate how long an existing LiFePO₄ or AGM battery bank runs DC and AC loads with usable capacity, inverter losses and K_temp to −10 °C.

Open calculator

Battery Bank Sizing Calculator (Ah & Wh)

Size a new 12V, 24V or 48V LiFePO₄ (85% DoD) or AGM (50% DoD) battery bank from daily DC/AC loads, autonomy days and cold factor K_temp.

Open calculator

Solar Array & MPPT Charge Controller Calculator

Check cold PV Voc up to 150 V DC, hot Vmp startup headroom, controller Isc limits and 1.25× parallel-string backfeed fuse sizing.

Open calculator

Inverter Size, Surge, Fuse & BMS Calculator

Verify worst-case DC current at low-voltage cutoff, startup surge duration, BMS peak limits, fuse DC voltage and interrupt rating (AIC).

Open calculator

DC Fuse Size & Interrupt Rating (AIC) Calculator

Find standard DC fuse ratings between 1.25× load current and derated cable ampacity, and verify DC voltage rating and AIC up to 60 V DC.

Open calculator

Battery Charge Time Calculator (Solar, DC-DC & Shore)

Estimate LiFePO₄ and AGM bulk plus absorption recharge time from charger amps or daily solar peak sun hours with concurrent loads and cold gates.

Open calculator

Solar Panel Tilt Angle & Orientation Calculator

Find seasonal, monthly and year-round solar tilt angles and True South/North azimuth by latitude, plus flat-roof noon direct-beam factors.

Open calculator

DC Electrical & Wire Converters (3)

Shared calculation baselines

Battery and DC bus voltage ceiling 12 V, 24 V and 48 V nominal, strictly ≤ 60 V DC across all charge stages
Off-grid PV cold open-circuit ceiling ≤ 150 V DC (touch protection and DC PV disconnect required above 60 V DC)
Copper resistivity at 75 °C (167 °F) 0.0209664 Ω·mm²/m on round-trip conductor length (2 × one-way)
Nominal voltages and usable DoD LiFePO₄: 12.8 / 25.6 / 51.2 V (85% default DoD); AGM: 12.0 / 24.0 / 48.0 V (50% DoD)
Cold-weather LiFePO₄ charging Verify BMS limit at ≤ +5 °C (41 °F); hard block at ≤ 0 °C (32 °F) without self-heating