Two site conditions change the choice immediately:
- Shore feed capacity and shared loads: A North American 120V/60Hz 15A pedestal or a UK/AU 230V/50Hz 10A hookup leaves minimal headroom once air conditioning, water heating, or cooking loads run. If shared AC loads cannot be shed manually, use an inverter-charger with programmable AC input-current limiting (power sharing) rather than a fixed-output converter.
- Battery chemistry: Upgrading from lead-acid to LiFePO4 (12.8V, 25.6V, or 51.2V nominal) requires disabling legacy equalization/desulfation pulses and matching absorb/float targets so the BMS does not trip on overvoltage or sit at an incorrect float voltage.
For how shore charging coordinates with solar MPPT and alternator sources on the same DC bus, see Battery Charging Sources.
Charger Architectures Compared
| Architecture | Typical Use Case | AC Input Budgeting | Chemistry & Voltage Control | Shared AC Load Handling |
|---|---|---|---|---|
| Standalone AC-DC Charger | Marine docks, off-grid cabins, dedicated LiFePO4 banks | Fixed max AC draw per nameplate; some units offer manual current derating | Dedicated multi-stage profiles (Bulk / Absorb / Float); often supports remote voltage/temp sense | None; user must size below remaining AC headroom or shed heavy loads |
| RV Converter-Charger / Central Motorhome Unit | North American RVs, European/UK/AU motorhomes with integrated 12V DC distribution | Fixed output; legacy units often have poor power factor (0.65–0.80), raising AC amps per DC watt | Legacy units default to 13.6V fixed float or 14.4V–15.5V lead-acid cycles; modern units include a LiFePO4 switch or jumper | None; shares the main AC distribution feed with HVAC and appliances |
| Inverter-Charger (Charger Mode) | Off-grid cabins, expedition vehicles, larger marine/RV banks | Programmable AC input-current limit (e.g., 5A–50A AC) with Power-Factor Correction (0.95–0.99) | Fully programmable absorb, float, tail current, and temperature compensation | Active throttling: automatically reduces DC charge current as shared AC loads rise |
DC Charge Profile Baselines (12V / 24V / 48V)
Verify exact setpoints on the battery datasheet and BMS specification. All DC bus and charging voltages must remain <=60V DC.
| Chemistry & Nominal Voltage | Bulk / Absorb Voltage | Float Voltage | Equalization Setting | Key Configuration Notes |
|---|---|---|---|---|
| LiFePO4 — 12.8V | 14.2V – 14.6V | 13.4V – 13.6V (or charger idle) | OFF / Disabled | Verify BMS max charge current; disable automatic desulfation |
| LiFePO4 — 25.6V | 28.4V – 29.2V | 26.8V – 27.2V (or charger idle) | OFF / Disabled | Avoid legacy 24V lead-acid profiles that spike above 29.2V |
| LiFePO4 — 51.2V | 56.8V – 58.4V | 53.6V – 54.4V (or charger idle) | OFF / Disabled | Remains <=60V DC; verify DC fuses are rated >58.4V |
| AGM / Sealed Lead-Acid — 12.0V | 14.4V – 14.7V | 13.5V – 13.8V | OFF (unless datasheet specifies) | Apply temperature compensation (-3 mV/°C/cell typical) |
| AGM / Sealed Lead-Acid — 24.0V | 28.8V – 29.4V | 27.0V – 27.6V | OFF (unless datasheet specifies) | Apply temperature compensation per battery nameplate |
| Flooded Lead-Acid — 12.0V | 14.4V – 14.8V | 13.2V – 13.5V | ~15.5V (manual, periodic) | Disconnect sensitive 12V DC loads during equalization |
| Flooded Lead-Acid — 24.0V | 28.8V – 29.6V | 26.4V – 27.0V | ~31.0V (manual, periodic) | Disconnect sensitive 24V DC loads during equalization |
Legacy Lead-Acid Settings on LiFePO4 Upgrades
When replacing lead-acid batteries with LiFePO4 in an RV converter-charger or central motorhome unit:
- Single-stage 13.6V converters will charge a 12.8V LiFePO4 bank slowly and never reach the 14.2V–14.6V absorb knee needed for top-balancing.
- Automatic equalization / desulfation timers on legacy 12V or 24V chargers pulse above 15.0V (12V) or 30.0V (24V), tripping the LiFePO4 BMS overvoltage cutoff. Replace the unit or lock out equalization if the controller cannot disable it.
- Cold-temperature charging: Flag ambient or cell temperatures <=+5°C (41°F) to verify the battery BMS minimum charge temperature (some commercial packs lock out at +5°C). Hard-block charging at <=0°C (32°F) unless the battery bank has an active self-heating system.
AC Input-Current Budgeting & Shared Load Headroom
Compute the charger's AC input current from its DC charging power, efficiency, and power factor (check the equipment nameplate for exact values):
I_ac = (V_dc_charge * I_dc_charge) / (V_ac * Efficiency * Power_Factor)
V_dc_charge: Maximum absorb voltage (V)I_dc_charge: DC charging current (A)V_ac: Shore nominal voltage (120VNorth America;230VUK/AU)Efficiency: Charger conversion efficiency (typically0.85–0.92)Power_Factor:0.95–0.99for PFC chargers;0.65–0.80for non-PFC converter-chargers
Illustrative Shore Budget Examples (Assumed Nameplate Values)
- North America 120V/60Hz, 15A pedestal (80% continuous budget = 12.0A / 1,440W):
An 80A 12V LiFePO4 charger at 14.6V (1,168W DC), assuming
Efficiency = 0.88andPower_Factor = 0.95, draws1168 / (120 * 0.88 * 0.95) = 11.6A AC. Adding a 600W (5.0A) shared appliance pushes total draw to16.6A ACand trips the 15A breaker. - UK/AU 230V/50Hz, 10A campsite supply (80% continuous budget = 8.0A / 1,840W):
A 35A 48V (51.2V nominal) LiFePO4 charger at 58.4V (2,044W DC), assuming
Efficiency = 0.90andPower_Factor = 0.98, draws2044 / (230 * 0.90 * 0.98) = 10.1A AC, exceeding the continuous budget before any shared cabin loads run. Setting an inverter-charger's AC input limit to8.0Athrottles DC charging to ~27A automatically when idle and further down when shared loads turn on.
Regional Shore Supply Reference (Zero Shared Loads)
| Region & Shore Rating | Nominal AC Power | 80% Continuous AC Budget | Illustrative Max DC Amps @ 14.6V (12V) | Illustrative Max DC Amps @ 29.2V (24V) | Illustrative Max DC Amps @ 58.4V (48V) |
|---|---|---|---|---|---|
| NA 120V/60Hz — 15A | 1,800W | 12.0A (1,440W) | ~82A | ~41A | ~20A |
| NA 120V/60Hz — 20A | 2,400W | 16.0A (1,920W) | ~110A | ~55A | ~27A |
| NA 120V/60Hz — 30A | 3,600W | 24.0A (2,880W) | ~165A | ~82A | ~41A |
| UK/AU 230V/50Hz — 10A | 2,300W | 8.0A (1,840W) | ~105A | ~52A | ~26A |
| UK/AU 230V/50Hz — 15A | 3,450W | 12.0A (2,760W) | ~158A | ~79A | ~39A |
| UK/AU 230V/50Hz — 16A | 3,680W | 12.8A (2,944W) | ~168A | ~84A | ~42A |
| UK/AU 230V/50Hz — 32A | 7,360W | 25.6A (5,888W) | ~337A (limit to BMS) | ~168A | ~84A |
Note: Illustrative DC limits assume Efficiency = 0.88, Power_Factor = 0.95. Subtract all concurrent AC appliance wattage directly from the continuous AC budget before sizing charger output.
DC-Side Sizing & Commissioning Steps
Keep all physical installation and wiring steps strictly on the DC side; verify AC shore connections only against the equipment's rated input plug, breaker, and input-limit settings.
- Confirm AC Input & Shared-Load Strategy
- Check the charger nameplate for maximum AC input amps and power factor.
- On an inverter-charger, set the AC input-current limit to 80% of the shore pedestal breaker (or lower if sharing a marina/campsite post) so charging throttles down automatically when shared AC loads run.
- Program the Chemistry & Cold-Charge Rules
- Select the exact bulk/absorb and float voltages for 12.8V, 25.6V, or 51.2V LiFePO4 (or 12V/24V AGM/flooded).
- Confirm equalization is OFF for LiFePO4 and AGM.
- Connect the battery temperature sensor or BMS communication link; verify low-temperature charge cut-off at <=0°C (32°F) (and check <=+5°C / 41°F BMS thresholds on commercial packs).
- Size DC Charging Conductors
- Measure the round-trip length (
L_rt = 2 * L_one_way) between charger DC terminals and the battery bus/shunt. - Calculate voltage drop using 75°C copper resistivity (
0.02097 ohm·mm²/m):V_drop = (I_dc_charge * L_rt_m * 0.02097) / Cross_Section_mm2 - Target <=3% voltage drop on charging runs so the charger does not sense absorb voltage prematurely.
- Select the larger conductor between the voltage-drop requirement and >=1.25x continuous ampacity (for >=3h bulk runs), honoring 75°C terminal temperature ratings and avoiding undersized SAE J1128 thin-wall or copper-clad aluminum (CCA) cable.
- Measure the round-trip length (
- Select DC Overcurrent Protection
- Place the fuse or DC breaker as close as practical to the positive battery bus.
- Verify
Fuse_Rating >= 1.25 * I_dc_chargeandFuse_Rating <= Cable_Ampacity. - Verify fuse maximum voltage >= maximum charging voltage: on 48V (51.2V) LiFePO4 charging to 58.4V, do not use 58V-rated terminal fuses—use 60V+ or 80V+ DC-rated fuses.
- Verify prospective battery fault current <= fuse AIC at operating voltage.
- Commission Under Load
- Verify DC polarity before energizing.
- Start a bulk charge and measure AC input current (confirming headroom with typical shared AC loads) and DC voltage at both charger terminals and battery terminals.
Sign-Off Criteria
- AC Headroom: Peak AC input draw (charger + expected shared AC loads) remains within the shore pedestal's 80% continuous rating, or the inverter-charger's input-current limiter throttles DC charge current without tripping the shore breaker.
- DC Voltage Accuracy: Measured absorb voltage at the battery terminals matches the programmed target within +/-0.1V (12V), +/-0.2V (24V), or +/-0.4V (48V), with <=3% voltage drop across the DC charge cables.
- Chemistry & Thermal Safety: Equalization is verified OFF for LiFePO4/AGM; cold-charge inhibit triggers at <=0°C (32°F) (or at the pack's <=+5°C / 41°F BMS limit).
- Protection & Terminations: DC fuse rating is <= cable ampacity, fuse voltage rating exceeds max absorb voltage (critical on 58.4V 48V LiFePO4), and terminal temperatures stay within 75°C ratings during sustained bulk charging.
Real Failure Modes
- Pedestal Breaker Nuisance Tripping: Running a non-PFC converter-charger (power factor 0.65–0.75) or an unthrottled charger alongside a water heater or HVAC unit exceeds 15A (120V) or 10A (230V) shore limits.
- BMS Overvoltage Disconnect from Legacy Profiles: Leaving a motorhome electrical unit or converter-charger in flooded lead-acid mode triggers a >15V (12V) or >30V (24V) desulfation/equalization pulse, opening the LiFePO4 BMS charge path and causing voltage transients on the DC bus.
- Premature Absorb Taper from Voltage Drop: Undersized DC charging cables or loose crimps create excessive voltage drop at full bulk current; the charger sees absorb voltage at its own terminals early and tapers current while the battery is still partially charged.
- Under-Rated Fuse Voltage on 48V LiFePO4: Installing a 58V-rated bolt-on terminal fuse on a 51.2V LiFePO4 bank that absorbs at 58.4V exceeds the fuse's voltage rating.
- Cold-Weather Cell Damage or Unexpected Lockout: Charging LiFePO4 at <=0°C (32°F) without self-heating causes permanent lithium plating, while commercial packs with a +5°C (41°F) BMS charge floor will abruptly reject shore charging in cool shoulder-season weather.
In this section
- Sizing Standalone AC Battery Chargers Size a standalone AC shore charger so its derated DC output meets recharge windows without exceeding bank charge current, BMS, or thermal limits.
- Central Motorhome Electrical Units and Lithium Upgrades Integrated motorhome units often lock in lead-acid or gel curves, requiring a lithium selector, charger disablement, or external bypass for LiFePO4.
- RV Converter-Chargers on Shore Power An RV converter-charger powers live 12V DC loads while charging, so legacy fixed-voltage units undercharge LiFePO4 and long wire runs taper early.
- Inverter-Charger Shore Charging and AC Input Limits Set both maximum DC charge current and the AC input ceiling on an inverter-charger so pass-through loads throttle charging before tripping pedestals.
- Legacy Lead-Acid Charger Settings After a Chemistry Change Before reusing a legacy shore charger, disable desulfation, high equalization, and cold boost sensors, and match absorption and float to the new bank.
- Multi-Bank AC Shore Chargers and Mixed Chemistries Multi-output AC chargers usually share one voltage profile across common-negative channels, so mixing lead-acid and LiFePO4 requires isolated outputs.
- North American 120V/60Hz Campsite and Marina Charger Budgeting On 120V/60Hz 15A, 20A, 30A, and split-phase 50A pedestals, budget continuous AC charger draw within 80% of one 120V leg, accounting for cord sag.
- Shared AC Loads and Shore Charging Headroom Concurrent AC loads draw shore-cord amps first, leaving battery charging only the remaining current after conversion efficiency and VA power factor.
- UK and Australian 230V/50Hz Campsite and Marina Charger Budgeting UK 6A-16A and Australian 10A/15A 230V/50Hz supplies deliver roughly twice the charging watts per amp of 120V if the charger is rated for 230V/50Hz.
Part of Solar Charge Controller Calculator and Battery Charging Guide