On this page

Two site conditions change the choice immediately:

  1. Shore feed capacity and shared loads: A North American 120V/60Hz 15A pedestal or a UK/AU 230V/50Hz 10A hookup leaves minimal headroom once air conditioning, water heating, or cooking loads run. If shared AC loads cannot be shed manually, use an inverter-charger with programmable AC input-current limiting (power sharing) rather than a fixed-output converter.
  2. Battery chemistry: Upgrading from lead-acid to LiFePO4 (12.8V, 25.6V, or 51.2V nominal) requires disabling legacy equalization/desulfation pulses and matching absorb/float targets so the BMS does not trip on overvoltage or sit at an incorrect float voltage.

For how shore charging coordinates with solar MPPT and alternator sources on the same DC bus, see Battery Charging Sources.


Charger Architectures Compared

Architecture Typical Use Case AC Input Budgeting Chemistry & Voltage Control Shared AC Load Handling
Standalone AC-DC Charger Marine docks, off-grid cabins, dedicated LiFePO4 banks Fixed max AC draw per nameplate; some units offer manual current derating Dedicated multi-stage profiles (Bulk / Absorb / Float); often supports remote voltage/temp sense None; user must size below remaining AC headroom or shed heavy loads
RV Converter-Charger / Central Motorhome Unit North American RVs, European/UK/AU motorhomes with integrated 12V DC distribution Fixed output; legacy units often have poor power factor (0.65–0.80), raising AC amps per DC watt Legacy units default to 13.6V fixed float or 14.4V–15.5V lead-acid cycles; modern units include a LiFePO4 switch or jumper None; shares the main AC distribution feed with HVAC and appliances
Inverter-Charger (Charger Mode) Off-grid cabins, expedition vehicles, larger marine/RV banks Programmable AC input-current limit (e.g., 5A–50A AC) with Power-Factor Correction (0.95–0.99) Fully programmable absorb, float, tail current, and temperature compensation Active throttling: automatically reduces DC charge current as shared AC loads rise

DC Charge Profile Baselines (12V / 24V / 48V)

Verify exact setpoints on the battery datasheet and BMS specification. All DC bus and charging voltages must remain <=60V DC.

Chemistry & Nominal Voltage Bulk / Absorb Voltage Float Voltage Equalization Setting Key Configuration Notes
LiFePO4 — 12.8V 14.2V – 14.6V 13.4V – 13.6V (or charger idle) OFF / Disabled Verify BMS max charge current; disable automatic desulfation
LiFePO4 — 25.6V 28.4V – 29.2V 26.8V – 27.2V (or charger idle) OFF / Disabled Avoid legacy 24V lead-acid profiles that spike above 29.2V
LiFePO4 — 51.2V 56.8V – 58.4V 53.6V – 54.4V (or charger idle) OFF / Disabled Remains <=60V DC; verify DC fuses are rated >58.4V
AGM / Sealed Lead-Acid — 12.0V 14.4V – 14.7V 13.5V – 13.8V OFF (unless datasheet specifies) Apply temperature compensation (-3 mV/°C/cell typical)
AGM / Sealed Lead-Acid — 24.0V 28.8V – 29.4V 27.0V – 27.6V OFF (unless datasheet specifies) Apply temperature compensation per battery nameplate
Flooded Lead-Acid — 12.0V 14.4V – 14.8V 13.2V – 13.5V ~15.5V (manual, periodic) Disconnect sensitive 12V DC loads during equalization
Flooded Lead-Acid — 24.0V 28.8V – 29.6V 26.4V – 27.0V ~31.0V (manual, periodic) Disconnect sensitive 24V DC loads during equalization

Legacy Lead-Acid Settings on LiFePO4 Upgrades

When replacing lead-acid batteries with LiFePO4 in an RV converter-charger or central motorhome unit:

  • Single-stage 13.6V converters will charge a 12.8V LiFePO4 bank slowly and never reach the 14.2V–14.6V absorb knee needed for top-balancing.
  • Automatic equalization / desulfation timers on legacy 12V or 24V chargers pulse above 15.0V (12V) or 30.0V (24V), tripping the LiFePO4 BMS overvoltage cutoff. Replace the unit or lock out equalization if the controller cannot disable it.
  • Cold-temperature charging: Flag ambient or cell temperatures <=+5°C (41°F) to verify the battery BMS minimum charge temperature (some commercial packs lock out at +5°C). Hard-block charging at <=0°C (32°F) unless the battery bank has an active self-heating system.

AC Input-Current Budgeting & Shared Load Headroom

Compute the charger's AC input current from its DC charging power, efficiency, and power factor (check the equipment nameplate for exact values):

I_ac = (V_dc_charge * I_dc_charge) / (V_ac * Efficiency * Power_Factor)
  • V_dc_charge: Maximum absorb voltage (V)
  • I_dc_charge: DC charging current (A)
  • V_ac: Shore nominal voltage (120V North America; 230V UK/AU)
  • Efficiency: Charger conversion efficiency (typically 0.85–0.92)
  • Power_Factor: 0.95–0.99 for PFC chargers; 0.65–0.80 for non-PFC converter-chargers

Illustrative Shore Budget Examples (Assumed Nameplate Values)

  • North America 120V/60Hz, 15A pedestal (80% continuous budget = 12.0A / 1,440W): An 80A 12V LiFePO4 charger at 14.6V (1,168W DC), assuming Efficiency = 0.88 and Power_Factor = 0.95, draws 1168 / (120 * 0.88 * 0.95) = 11.6A AC. Adding a 600W (5.0A) shared appliance pushes total draw to 16.6A AC and trips the 15A breaker.
  • UK/AU 230V/50Hz, 10A campsite supply (80% continuous budget = 8.0A / 1,840W): A 35A 48V (51.2V nominal) LiFePO4 charger at 58.4V (2,044W DC), assuming Efficiency = 0.90 and Power_Factor = 0.98, draws 2044 / (230 * 0.90 * 0.98) = 10.1A AC, exceeding the continuous budget before any shared cabin loads run. Setting an inverter-charger's AC input limit to 8.0A throttles DC charging to ~27A automatically when idle and further down when shared loads turn on.

Regional Shore Supply Reference (Zero Shared Loads)

Region & Shore Rating Nominal AC Power 80% Continuous AC Budget Illustrative Max DC Amps @ 14.6V (12V) Illustrative Max DC Amps @ 29.2V (24V) Illustrative Max DC Amps @ 58.4V (48V)
NA 120V/60Hz — 15A 1,800W 12.0A (1,440W) ~82A ~41A ~20A
NA 120V/60Hz — 20A 2,400W 16.0A (1,920W) ~110A ~55A ~27A
NA 120V/60Hz — 30A 3,600W 24.0A (2,880W) ~165A ~82A ~41A
UK/AU 230V/50Hz — 10A 2,300W 8.0A (1,840W) ~105A ~52A ~26A
UK/AU 230V/50Hz — 15A 3,450W 12.0A (2,760W) ~158A ~79A ~39A
UK/AU 230V/50Hz — 16A 3,680W 12.8A (2,944W) ~168A ~84A ~42A
UK/AU 230V/50Hz — 32A 7,360W 25.6A (5,888W) ~337A (limit to BMS) ~168A ~84A

Note: Illustrative DC limits assume Efficiency = 0.88, Power_Factor = 0.95. Subtract all concurrent AC appliance wattage directly from the continuous AC budget before sizing charger output.


DC-Side Sizing & Commissioning Steps

Keep all physical installation and wiring steps strictly on the DC side; verify AC shore connections only against the equipment's rated input plug, breaker, and input-limit settings.

  1. Confirm AC Input & Shared-Load Strategy
    • Check the charger nameplate for maximum AC input amps and power factor.
    • On an inverter-charger, set the AC input-current limit to 80% of the shore pedestal breaker (or lower if sharing a marina/campsite post) so charging throttles down automatically when shared AC loads run.
  2. Program the Chemistry & Cold-Charge Rules
    • Select the exact bulk/absorb and float voltages for 12.8V, 25.6V, or 51.2V LiFePO4 (or 12V/24V AGM/flooded).
    • Confirm equalization is OFF for LiFePO4 and AGM.
    • Connect the battery temperature sensor or BMS communication link; verify low-temperature charge cut-off at <=0°C (32°F) (and check <=+5°C / 41°F BMS thresholds on commercial packs).
  3. Size DC Charging Conductors
    • Measure the round-trip length (L_rt = 2 * L_one_way) between charger DC terminals and the battery bus/shunt.
    • Calculate voltage drop using 75°C copper resistivity (0.02097 ohm·mm²/m):
      V_drop = (I_dc_charge * L_rt_m * 0.02097) / Cross_Section_mm2
      
    • Target <=3% voltage drop on charging runs so the charger does not sense absorb voltage prematurely.
    • Select the larger conductor between the voltage-drop requirement and >=1.25x continuous ampacity (for >=3h bulk runs), honoring 75°C terminal temperature ratings and avoiding undersized SAE J1128 thin-wall or copper-clad aluminum (CCA) cable.
  4. Select DC Overcurrent Protection
    • Place the fuse or DC breaker as close as practical to the positive battery bus.
    • Verify Fuse_Rating >= 1.25 * I_dc_charge and Fuse_Rating <= Cable_Ampacity.
    • Verify fuse maximum voltage >= maximum charging voltage: on 48V (51.2V) LiFePO4 charging to 58.4V, do not use 58V-rated terminal fuses—use 60V+ or 80V+ DC-rated fuses.
    • Verify prospective battery fault current <= fuse AIC at operating voltage.
  5. Commission Under Load
    • Verify DC polarity before energizing.
    • Start a bulk charge and measure AC input current (confirming headroom with typical shared AC loads) and DC voltage at both charger terminals and battery terminals.

Sign-Off Criteria

  • AC Headroom: Peak AC input draw (charger + expected shared AC loads) remains within the shore pedestal's 80% continuous rating, or the inverter-charger's input-current limiter throttles DC charge current without tripping the shore breaker.
  • DC Voltage Accuracy: Measured absorb voltage at the battery terminals matches the programmed target within +/-0.1V (12V), +/-0.2V (24V), or +/-0.4V (48V), with <=3% voltage drop across the DC charge cables.
  • Chemistry & Thermal Safety: Equalization is verified OFF for LiFePO4/AGM; cold-charge inhibit triggers at <=0°C (32°F) (or at the pack's <=+5°C / 41°F BMS limit).
  • Protection & Terminations: DC fuse rating is <= cable ampacity, fuse voltage rating exceeds max absorb voltage (critical on 58.4V 48V LiFePO4), and terminal temperatures stay within 75°C ratings during sustained bulk charging.

Real Failure Modes

  • Pedestal Breaker Nuisance Tripping: Running a non-PFC converter-charger (power factor 0.65–0.75) or an unthrottled charger alongside a water heater or HVAC unit exceeds 15A (120V) or 10A (230V) shore limits.
  • BMS Overvoltage Disconnect from Legacy Profiles: Leaving a motorhome electrical unit or converter-charger in flooded lead-acid mode triggers a >15V (12V) or >30V (24V) desulfation/equalization pulse, opening the LiFePO4 BMS charge path and causing voltage transients on the DC bus.
  • Premature Absorb Taper from Voltage Drop: Undersized DC charging cables or loose crimps create excessive voltage drop at full bulk current; the charger sees absorb voltage at its own terminals early and tapers current while the battery is still partially charged.
  • Under-Rated Fuse Voltage on 48V LiFePO4: Installing a 58V-rated bolt-on terminal fuse on a 51.2V LiFePO4 bank that absorbs at 58.4V exceeds the fuse's voltage rating.
  • Cold-Weather Cell Damage or Unexpected Lockout: Charging LiFePO4 at <=0°C (32°F) without self-heating causes permanent lithium plating, while commercial packs with a +5°C (41°F) BMS charge floor will abruptly reject shore charging in cool shoulder-season weather.