On this page

The pedestal breaker stays closed because none of these faults draw sustained overcurrent. Instead, the charger or inverter-charger opens its internal input relay to protect itself or the battery bank, waits through a built-in qualification delay, and closes back in once the input appears valid or internal temperatures drop. If the unit drops charging and AC pass-through output also fails while shore voltage at the inlet remains within nameplate limits, treat the fault as an AC transfer or output-stage issue under Inverter and AC Output Troubleshooting. For broader shore-power symptoms—such as zero charging from the moment of plug-in or immediate breaker trips—start at the Shore Charging Troubleshooting index.

Competing Causes and Acceptance Specifications

Chargers and inverter-chargers qualify incoming shore power continuously against four boundaries: AC RMS voltage, AC frequency, available current before voltage collapse, and internal heatsink/ambient temperature. Check the equipment nameplate and manual for exact qualification thresholds and transfer-delay timers before replacing hardware.

Competing Cause Primary Symptom Pattern Key Measurement or Check 120 V / 60 Hz (North America) vs. 230 V / 50 Hz (UK/AU)
Weak-supply voltage sag Drops only during high-current bulk charging; recovers seconds after disconnect Measure AC voltage at the shore inlet under full bulk load vs. no load Typical nominal 120 V AC (common charger low-line cutoff ~90–105 V AC) vs. 230 V AC (common cutoff ~180–195 V AC)
Frequency drift Drops at any charge current, especially on loaded pedestals, inverters, or portable generators Measure input frequency (Hz) at the inlet during the dropout 60 Hz nominal (typical window ~55–65 Hz) vs. 50 Hz nominal (typical window ~45–55 Hz)
Degraded inlet or cord contact Drops after 5–30 minutes of bulk charging; plug blades or inlet pins feel hot Inspect cord-end blades and inlet pins for discoloration, pitting, or loose retention; check voltage drop across the cord High-resistance contacts heat up under 15 A / 30 A (120 V) or 16 A (230 V) continuous draw and sag locally
Charger thermal cycling Drops after sustained bulk charging in warm enclosures; long cooldown before restart Check enclosure intake/exhaust airflow, fan operation, and ambient temperature Derating often begins around 104°F–122°F (40°C–50°C) ambient; check nameplate derating curve
DC-side or BMS cycling (mimic) AC input stays qualified, but charge current cycles to zero repeatedly Check DC bus voltage, DC terminal temperature, and BMS charge-enable state Applies across 12 V (12.8 V LiFePO4), 24 V (25.6 V), and 48 V (51.2 V) banks; verify cold-charge lockout at <=41°F (5°C) / <=32°F (0°C)

Illustrative Load and Voltage-Sag Math

On a shore hookup, AC input power tracks DC charging power plus conversion losses:

P_ac_in = (V_dc * I_dc) / charger_efficiency I_ac_in = P_ac_in / (V_ac * power_factor)

Illustrative example (assumptions: 12.8 V nominal LiFePO4 charging at 14.4 V absorb, 80 A DC output, 88% charger efficiency, 0.95 power factor):

  • P_dc = 14.4 V * 80 A = 1,152 W
  • P_ac_in = 1,152 W / 0.88 = 1,309 W
  • On a 120 V / 60 Hz hookup: I_ac_in = 1,309 W / (120 V * 0.95) = 11.5 A (if voltage sags to 102 V, current rises to 1,309 / (102 * 0.95) = 13.5 A, accelerating cord heating and further sag).
  • On a 230 V / 50 Hz hookup: I_ac_in = 1,309 W / (230 V * 0.95) = 6.0 A.

Long or undersized extension cords compound weak pedestals. Using a 100 ft (30.5 m) 14 AWG (2.08 mm²) adapter cord instead of a 25 ft (7.6 m) 10 AWG (5.26 mm²) shore cord at 15 A on 120 V AC can add over 7 V of cord drop alone, pushing a marginally low 110 V pedestal right past a 103 V charger low-line cutoff as soon as bulk charging ramps up.

Ordered Diagnostic Checks

Work through these checks in order so you separate external supply faults from cord/inlet faults, charger configuration limits, and DC-side cutoffs without guessing.

  1. Check charger status codes and input limits first. Read the charger or inverter-charger status display, LED blink code, or telemetry log before touching hardware. Confirm the programmed AC input current limit matches the shore cord and pedestal rating (for example, 15 A or 30 A on 120 V North American hookups; 10 A or 16 A on 230 V UK/AU hookups) and that low-voltage cutoff or power-sharing/assist thresholds are not set higher than normal for your region.

  2. Measure shore voltage and frequency unloaded, then under bulk load. Measure AC voltage and frequency at the pedestal receptacle with no load, then at the vehicle or vessel inlet (or via the inverter-charger's live AC-in readout) while bulk charging ramps up.

    • If pedestal voltage itself drops more than 5%–8% under load or frequency drifts outside the charger's nameplate window, the pedestal, park wiring, or upstream generator is the cause.
    • If the pedestal holds steady at 118–122 V (or 225–235 V) while the inlet sags sharply under load, the fault sits in the shore cord, adapter, or inlet connection.
  3. Inspect the shore cord, adapters, and inlet interface. Unplug the shore cord and inspect plug blades, twist-lock contacts, and the shore-power inlet pins for heat tinting, melted plastic, corrosion, or loose spring tension. Remove stacked adapters (such as 30 A-to-15 A dogbones paired with long household extension cords) and test directly with the shortest rated shore cord available—ideally 25 ft (7.6 m) or shorter at full gauge (10 AWG / 5.26 mm² for 30 A 120 V; 12 AWG / 3.31 mm² for 15–20 A 120 V; 2.5 mm² for 16 A 230 V).

  4. Check charger cooling and enclosure airflow. If dropouts only occur after 15–45 minutes of high-output charging and restart after a cooldown pause, check intake vents, dust screens, and internal cooling fans. Verify at least the manufacturer's minimum clearance around the unit and measure enclosure air temperature near the charger intake. Values above 104°F (40°C) trigger output derating or thermal shutdown on many marine and RV chargers.

  5. Isolate DC-bus and BMS charge-cutoff mimics (<=60 V DC side). If AC input voltage and frequency remain stable at the charger while charging still cycles on and off, inspect the DC side (12 V / 24 V / 48 V nominal, strictly <=60 V DC):

    • Measure DC voltage directly at the charger's DC output studs and compare it to the battery bank terminals during bulk charge. A rising voltage gap (>0.3 V on 12 V, >0.6 V on 24 V, >1.2 V on 48 V) indicates a loose DC lug, corroded terminal fuse, or failing DC disconnect switch causing the charger to hit absorption voltage prematurely (14.2–14.6 V for 12.8 V LiFePO4; 28.4–29.2 V for 25.6 V; 56.8–58.4 V for 51.2 V) and drop back to float or idle.
    • Verify battery temperature and BMS charge state. Commercial LiFePO4 packs often lock out charging at <=41°F (5°C) and hard-block charging at <=32°F (0°C) unless self-heated; an unheated battery hovering near its BMS cutoff threshold will repeatedly open and close its charge FETs as cell temperature or voltage fluctuates.
    • Confirm DC fuse voltage and ampacity ratings match the system (for example, a 58 V-rated terminal fuse is undersized for a 51.2 V LiFePO4 bank charging to 58.4 V). Tighten DC terminal hardware to the manufacturer's torque specification on clean, bare-metal contact surfaces.
  6. Evaluate internal transfer relay and input-stage faults. When AC voltage and frequency at the charger terminals stay inside the nameplate window, temperatures are normal, and the DC bus is solid, yet the input relay still chatters or drops out—especially if AC pass-through loads also lose power—escalate to Inverter and AC Output Troubleshooting.

Sign-Off Criteria

Confirm the repair under full sustained load before returning the system to unattended shore power:

  • Stable AC qualification: Input voltage at the charger/inlet remains within the nameplate acceptance window (typically >=108 V AC on a 120 V / 60 Hz hookup, or >=207 V AC on a 230 V / 50 Hz hookup) and within +/-1 Hz of nominal throughout peak bulk charging.
  • Zero thermal or contact runaways: Cord plugs, adapters, and inlet pins remain cool to warm—never hot to the touch—after 30 minutes at maximum programmed AC input current, and charger intake air stays below the nameplate derating threshold.
  • Uninterrupted bulk-to-absorption transition: The charger completes a full bulk ramp up to absorption voltage (14.2–14.6 V / 28.4–29.2 V / 56.8–58.4 V for LiFePO4; bank-specific target for AGM) without relay dropouts or BMS charge-FET cycling.

Real Failure Modes

  • Oxidized twist-lock or smart-plug contacts: A slightly pitted neutral or hot pin passes open-circuit voltage tests cleanly, then heats under 12–25 A bulk current, raising contact resistance until local voltage sags below the charger's low-line threshold.
  • Stacked adapters and long light-gauge cords: Using a 16 AWG (1.31 mm²) or 14 AWG (2.08 mm²) household extension cord over 50–100 ft (15–30 m) on a 120 V pedestal drops voltage enough to trip the charger's low-line relay every time the DC bank pulls maximum bulk current.
  • Oversized AC input limit on a weak pedestal: Setting an inverter-charger's AC input current limit to 30 A while plugged into a sagging 15 A or 20 A circuit lets the charger pull full power until supply voltage collapses, causing an endless drop-and-reconnect loop.
  • Sealed-compartment heat soak: Mounting a fan-cooled charger in an unventilated battery locker or lazarette traps waste heat; the unit hits its thermal ceiling, drops charging to cool down, and restarts 10–15 minutes later.
  • High-resistance DC lug or cold BMS threshold: A loose DC negative lug or a LiFePO4 BMS hovering at 32°F–41°F (0°C–5°C) interrupts DC current flow, which looks like an AC shore-charging dropout on basic battery monitors even though the AC input never disconnected.