This reference sits under the DC Power Systems Hub and defines the complete architecture, bill of materials, sizing math, and commissioning checks for small open craft.


System Selection & Voltage Baselines

Small craft have tight weight, buoyancy, and salt-spray limits. Raising bus voltage from 12V to 24V or 48V cuts propulsion current by 50% or 75%, shrinking cable gauge and terminal heat without exceeding the 60V DC touch-safety ceiling.

Platform Profile Primary Loads Recommended Bus Typical Bank Size (Illustrative) Enclosure & Mounting House 12V Feed
Paddle Craft & Kayak (Electronics Only) Fishfinder, GPS, nav lights, USB/VHF 12V (12.8V LiFePO4) 20–50 Ah (256–640 Wh nominal) Removable IP67 dry box; quick-disconnect plug Direct 12V fused bus
Electric Kayak & Small Tender (<=700 W) Light electric motor (<=55 lb thrust), nav lights 12V (12.8V LiFePO4) 50–100 Ah (640–1,280 Wh nominal) Secured IP67 battery box; quick-release Anderson-style or marine plug Direct 12V with dedicated propulsion and house fuses
Mid-Power Tender & Sailing Dinghy (1–2 kW) Mid-thrust electric outboard, bilge pump, chartplotter, VHF 24V (25.6V LiFePO4) 50–100 Ah (1,280–2,560 Wh nominal) Fixed or removable strapped marine case; drip-looped entry Isolated 24V-to-12V DC-DC converter
Open Skiff & Australian Aluminium Utility Boat (2–5 kW+) High-thrust electric outboard, bilge, deck wash, sounder, lighting 48V (51.2V LiFePO4) or 24V 60–100+ Ah at 51.2V (3,072–5,120+ Wh nominal) Rigid bolted tray with splash cover; isolated from aluminium hull Isolated 48V-to-12V DC-DC converter

Battery Chemistry & Operating Windows

  • LiFePO4 (Default for weight-sensitive craft): 12.8V / 25.6V / 51.2V nominal; typical absorption 14.2–14.6V / 28.4–29.2V / 56.8–58.4V; usable Depth of Discharge (DoD) 80–90% (85% default planning baseline).
  • AGM / Sealed Lead-Acid (Budget or sub-freezing cranking/aux): 12.0V / 24.0V / 48.0V nominal; usable DoD 50%.
  • Strict Voltage Ceiling: All battery banks, chargers, and DC buses must remain <=60V DC at peak charge. Because 51.2V LiFePO4 absorption reaches 58.4V, all fuses, switches, and DC-DC converters on a 48V nominal bus must be rated for >=60V DC (do not use 58V-rated terminal fuses on a 51.2V bank).
  • Cold Charging Protection: Verify the battery BMS minimum charge temperature on the datasheet—some commercial LiFePO4 packs lock out charging at <=+5°C (41°F), and charging is hard-blocked at <=0°C (32°F) unless the pack has an active internal self-heating circuit.

Bill of Materials (BOM) by Subsystem

Verify exact continuous current, surge duration, and terminal temperature ratings on each component nameplate before ordering.

Subsystem Required Specification Small Craft Notes
Battery Pack Marine-rated sealed LiFePO4 (12.8V / 25.6V / 51.2V) or AGM Must state continuous discharge amps >= motor full-throttle draw and peak surge duration >= startup/weed-clearing draw.
Primary Overcurrent Protection >=60V DC rated (48V bus) or >=32V DC rated (12V/24V bus); AIC >= prospective fault current Mount within 7 in (180 mm) of the positive battery post (e.g., Class-T for high-fault LiFePO4 banks, or properly voltage-rated MRBF).
Main Disconnect Switch Marine ignition-protected rotary or toggle switch; continuous rating >=1.25x continuous load Accessible without opening the battery lid; breaks positive feed (or double-pole positive + negative on aluminium hulls).
Distribution & Branch Fusing Sealed IP66+ fuse block with negative busbar (ATC/ATO or MIDI/AMI) Label every circuit (Bilge, Nav, Sounder, Propulsion). Never fuse the negative conductor in a standard single-pole system.
Conductors Tinned copper, marine-grade, 105°C dry / 75°C wet insulation, AWG-sized Never use SAE J1128 automotive wire or Copper-Clad Aluminium (CCA). Size terminals for 75°C max rating.
Terminations & Sealing Heavy-wall tinned copper lugs + adhesive-lined dual-wall heat shrink Crimp with a calibrated hex/indent crimper; seal every strand against capillary salt-water wicking.
12V House Converter (24V/48V boats) Isolated DC-DC buck converter (24V->12V or 48V->12V), IP67 potted Size continuous output >=1.25x simultaneous 12V loads (bilge + VHF + nav + sounder).
Charging / Portable Solar Marine IP65+ shore charger OR compact MPPT solar controller Shore charger must match chemistry absorb voltage. For PV: cold Voc < MPPT_Vmax, <=150V DC max (add disconnect and touch-safety guarding if >60V DC), Isc <= MPPT_Isc_max, hot Vmp inside controller window.
Optional Portable AC Interface Portable power station or compact inverter (120V/60Hz NA; 230V/50Hz UK/AU) Keep removable/self-contained on open craft. Verify continuous W, surge W, DC input port current limits (do not assume a 120W car-socket limit), conversion losses, and idle tare draw.

Engineering Sizing & Calculation Steps

Step 1: Compute Usable Energy & Propulsion Runtime

  1. List propulsion continuous power (P_prop in W) and house loads (P_house in W) multiplied by hours of operation (t_hours).
  2. Calculate required nominal battery Wh: Wh_bank = (P_total * t_hours) / (DoD * converter_efficiency) (Use DoD = 0.85 for LiFePO4, 0.50 for AGM; use converter_efficiency = 0.90 for loads fed through a DC-DC converter, 1.0 for direct bus loads.)

Step 2: Calculate Worst-Case DC Current

Size cables and fuses for maximum current at low-voltage cutoff (V_min), not nominal voltage: I_dc_max = P_load / (V_min * efficiency)

  • Illustrative Example (24V Open Utility Skiff):
    • Load: 1,200 W electric outboard; V_min = 21.6 V (nameplate cutoff); drivetrain/controller efficiency = 0.85 (verify on motor nameplate).
    • I_dc_max = 1200 / (21.6 * 0.85) = 65.4 A
    • Continuous (>=3h) derated ampacity target: 65.4 A * 1.25 = 81.8 A

Step 3: Size Conductors (Voltage Drop vs. Derated Ampacity)

Always use round-trip length (2 * L_one_way). Use 75°C copper resistivity = 0.02097 ohm·mm²/m.

  • Critical circuits (propulsion, bilge pump, navigation lights, VHF): <=3% voltage drop.
  • Non-critical circuits (deck work lights, USB outlets): <=10% voltage drop.

Plain-text cross-section formula: A_min (mm²) = (2 * L_one_way_m * I_dc_max * 0.02097) / (V_nominal * drop_limit)

  • Illustrative Example A (24V Propulsion Run, 8 ft / 2.44 m one-way, 3% drop):
    • Round-trip length: 2 * 2.44 m = 4.88 m
    • Allowed drop: 25.6 V * 0.03 = 0.768 V
    • A_min = (4.88 * 65.4 * 0.02097) / 0.768 = 8.71 mm²
    • Selection: 8 AWG (8.37 mm²) is slightly undersized for 3% drop and 81.8 A continuous ampacity; step up to 6 AWG (13.3 mm²), which yields 0.503 V (1.96% drop) and meets 75°C terminal ampacity.
  • Illustrative Example B (12V Bilge + Nav Branch, 15 ft / 4.57 m one-way, 10 A load, 3% drop):
    • Round-trip length: 2 * 4.57 m = 9.14 m
    • Allowed drop: 12.8 V * 0.03 = 0.384 V
    • A_min = (9.14 * 10 * 0.02097) / 0.384 = 4.99 mm²
    • Selection: 10 AWG (5.26 mm²) gives 0.364 V (2.85% drop).

Step 4: Verify Fuses, Surges & Aluminium Hull Isolation

  1. Fuse vs. Cable: I_dc_max <= Fuse_rating <= Cable_ampacity_75C. For the 24V 6 AWG example (65.4 A max, 81.8 A 1.25x target), an 80 A or 90 A fuse protects the 6 AWG marine cable without nuisance tripping.
  2. Voltage & AIC: Verify Fuse_Vmax >= Max_charge_voltage (e.g., >=60V DC for a 51.2V LiFePO4 bank) and Fuse_AIC >= Battery_short_circuit_current.
  3. Surge Alignment: Check motor locked-rotor/startup surge against the battery BMS peak duration and the fuse time-current curve so a weed-fouled prop trips the motor controller or fuse before the BMS latches off and kills steering/electronics.
  4. Aluminium Hull Isolation: Route dedicated positive and negative conductors to every load. Keep all terminal blocks, busbars, and negative returns isolated on non-conductive HDPE/starboard backing plates.

Commissioning & Sign-Off Criteria

Before launching, verify every item below with a multimeter and physical inspection:

  • Fuse Placement & Rating: Primary fuse sits within 7 in (180 mm) of the positive battery post; voltage rating >= max charge voltage (>=60V DC for 48V LiFePO4).
  • Two-Wire Hull Isolation (Aluminium Craft): With battery negative connected and loads off, resistance between the DC negative busbar and bare hull aluminium measures >1 MΩ (no unintended hull ground).
  • Full-Load Voltage Drop: Under maximum continuous propulsion + house load, voltage drop between battery terminals and motor/critical busbar measures <=3%.
  • Thermal & Torque Check: After 10 minutes at high load, all lugs, switch studs, and fuse holders are cool to the touch; all terminal fasteners are torqued to manufacturer spec with lock washers.
  • Bilge & Nav Independence: Turning off the propulsion branch or tripping the propulsion breaker leaves the bilge pump, VHF, and navigation lights operational.
  • Cold-Charge Check: If operating near or below +5°C (41°F), confirm BMS low-temperature charge cutoff behavior in the manual so solar/shore chargers do not damage cells or leave the system deadlocked.

Real Failure Modes

  • 58V Terminal Fuse Arcing on 51.2V LiFePO4: Standard 58V-rated MRBF terminal fuses are below the 58.4V absorption voltage of a 16-cell LiFePO4 bank and can fail to clear a fault cleanly. Always specify >=60V DC Class-T or >=60V-rated fuses on 48V systems.
  • Stray-Current Pitting on Aluminium Utility Boats: Using the aluminium hull as a negative return, or letting a wet bilge submerge an unsealed crimp, turns the hull into a sacrificial anode and causes rapid pitting around rivets, welds, and transducer mounts.
  • Automotive Wire & CCA Voltage Collapse: SAE J1128 thin-wall wire or Copper-Clad Aluminium (CCA) has higher resistance and poor salt-fog corrosion resistance; under high propulsion draw, voltage sags below V_min and triggers premature controller or BMS low-voltage cutoff miles from shore.
  • Capillary Salt-Water Wicking: Un-tinned copper and bare non-adhesive heat shrink wick salt spray inches up the cable jacket, turning strands green/black and spiking joint resistance until terminals melt.
  • Unexpected Cold-Weather Charge Lockout: Leaving a LiFePO4 pack on a solar trickle charger below +5°C (41°F) or 0°C (32°F) triggers BMS charge FET lockout; if the BMS separates charge and discharge paths or latches off, the user discovers a dead or uncharged battery at the ramp.