How AC Pass-Through Switchover Works

In an offline pass-through topology, the AC output is tied to the AC input through an electromechanical or solid-state transfer relay whenever incoming power is valid:

[AC Input: 120V/60Hz or 230V/50Hz]
        |
        +---> [AC-DC Charger] ---> [Internal Battery (<= 60V DC)] ---> [DC Ports (0 ms)]
        |                                       |
        v (Normal: Relay Closed)                v (Outage / Out-of-Window: Relay Open)
  [Transfer Relay] <-------------------- [DC-AC Inverter]
        |
        v
[AC Output Receptacles]

Two timing and electrical behaviours govern what happens at the receptacles:

  1. AC Output Interruption (t_transfer): When AC input fails, the controller must detect the fault (t_detect), open the input relay (t_relay), and ramp the DC-AC inverter to rated voltage (t_inv_start). The total dead time is: t_transfer = t_detect + t_relay + t_inv_start At North America's 120V / 60 Hz baseline, one full AC cycle lasts 1 / 60 Hz = 16.67 ms (half-cycle = 8.33 ms). In UK/AU 230V / 50 Hz regions, one full cycle lasts 1 / 50 Hz = 20.0 ms (half-cycle = 10.0 ms). A 10 ms transfer window drops roughly half a cycle; a 30 ms window drops nearly two full cycles.
  2. DC Output Continuity (0 ms): USB-C, 12V/24V regulated DC ports, and DC barrel outputs draw directly from the internal battery and DC-DC converters, not from the AC transfer relay. They experience 0 ms interruption when AC input drops.

EPS vs. UPS Claims and Load Behaviour

Manufacturers label pass-through switchover as UPS (Uninterruptible Power Supply) or EPS (Emergency Power Supply) based on the transfer duration. Neither is a true online double-conversion UPS (0 ms, where the inverter runs 100% of the time).

Classification / Load Type Typical Transfer Time (t_transfer) AC Cycles Lost (60 Hz / 50 Hz) Ride-Through Mechanism & Governing Threshold Expected Behaviour on Switchover
Online Double-Conversion UPS (Reference baseline, rare in portable stations) 0 ms 0 / 0 Continuous DC-to-AC inversion; input only charges battery Zero interruption; immune to input frequency/phase steps
Station "UPS" Mode <= 10 ms to 15 ms (check nameplate/spec) 0.6–0.9 / 0.5–0.75 Relies on load PSU bulk capacitor holdup time (t_holdup) Keeps most desktop PCs, routers, and monitors running if t_holdup > t_transfer
Station "EPS" Mode 20 ms to 30+ ms (check nameplate/spec) 1.2–1.8+ / 1.0–1.5+ Exceeds bulk capacitor holdup on heavily loaded electronics Sensitive electronics commonly reboot; lighting, heaters, and fridges ride through
Sensitive Switch-Mode Electronics (PCs, NAS, network gear, CPAP AC bricks) Governed by PSU t_holdup (typically 10–16 ms at full load) Must stay below t_holdup Bulk DC bus capacitors discharge during t_transfer Clean ride-through if t_transfer < t_holdup; hard reboot or brownout fault if t_transfer >= t_holdup
Inductive / Motor Loads (120V/230V compressors, fans, pumps) Tolerates 20–30 ms gap, sensitive to phase step 1–2 cycles Rotor inertia carries shaft; inrush occurs if inverter restarts out of phase Usually rides through short transfers; out-of-phase reconnection can trip inverter surge limits
Resistive Loads (Heaters, kettles, incandescent lamps) Tolerates 30+ ms 2+ cycles Thermal inertia; no internal logic or capacitors Brief flicker or minor heat dip; resumes immediately without fault

Note on illustrative values: Transfer times (10–30 ms) and PSU holdup times (10–16 ms) vary by hardware design and load percentage. Always verify the exact t_transfer specification on the portable station datasheet and the holdup rating on the connected power supply.

Verification and Sizing Steps

  1. Check Nameplate AC Ratings (120V/60Hz or 230V/50Hz): Record the station's maximum pass-through current/wattage and its inverter-only continuous and surge wattage. In many stations, pass-through allows higher current (e.g., 15 A / 1,800 W at 120V AC, or 10 A / 2,300 W at 230V AC) than the internal inverter can sustain once grid power fails.
  2. Verify Transfer Time and Trip Windows: Check the datasheet for the published t_transfer (ms) and the AC input voltage/frequency trip thresholds (undervoltage, overvoltage, and frequency tolerance in Hz).
  3. Match Load Holdup Time (t_holdup) to t_transfer: Confirm t_holdup > t_transfer for critical AC electronics. Where a critical load (such as a router or CPAP) accepts DC input, bypass the AC transfer relay entirely by powering it from the station's DC output ports (0 ms switchover) and verify the DC port's continuous current/wattage limit rather than assuming a universal 120 W car-socket ceiling.
  4. Verify Battery Reserve and Inverter Load Capacity: Size usable battery capacity (Wh_usable) for the expected outage duration after accounting for inverter conversion efficiency and idle tare draw: Runtime (h) = (Nominal_Wh * Usable_DoD * Inverter_Eff) / (Load_W + Inverter_Idle_W) (Illustrative example: a 1,024 Wh LiFePO4 station at 85% default usable DoD, 88% inverter efficiency, and 20 W idle draw supporting a 150 W load yields (1024 * 0.85 * 0.88) / (150 + 20) = 4.5 hours.)
  5. Check Cold-Charging Constraints for Standby Use: If the station is staged in an unheated cabin, vehicle, or boat below +5 °C (41 °F), verify the BMS minimum charge temperature on the datasheet. Below 0 °C (32 °F), charging is hard-blocked unless the battery is self-heated—meaning AC pass-through can feed the load, but the internal battery will not recharge while cold.

Sign-Off Criteria

  • Transfer Margin: Published t_transfer is strictly less than the connected critical load's rated t_holdup (or the critical load is moved to a 0 ms DC port).
  • Inverter-Only Continuity: Total connected AC watts (continuous and motor starting surge) do not exceed the station's inverter-only continuous and surge ratings—not just its pass-through wall rating.
  • Regional Input Match: AC input voltage and frequency match the local supply (120V / 60Hz in North America; 230V / 50Hz in UK/AU) within the station's published trip window.
  • Thermal Readiness: Ambient storage/operating temperature is above the BMS charge cutoff (> 0 °C / 32 °F, and verified above +5 °C / 41 °F if applicable) whenever the station relies on pass-through to maintain battery state of charge.

Failure Modes

  • Relay Chattering on Unstable Generators or Shore Power: If an AC generator or long shore-power cord sags in voltage or drifts in frequency near the station's trip threshold, the transfer relay rapidly cycles between pass-through and inverter mode, causing repeated t_transfer dropouts and thermal stress on the relay contacts.
  • Pass-Through Overload on Outage: Connected loads sized up to the wall pass-through limit (for example, 1,800 W at 120V AC) exceed a smaller internal inverter (for example, 1,200 W continuous). The system runs normally while grid power is present, then trips the inverter on overload the instant grid power fails.
  • Holdup Underrun Under High PSU Load: A computer or server power supply that rides through a 15 ms switchover at 30% load drops out at 80% load because bulk capacitor holdup time shrinks as output current rises.
  • Phase-Step Surge on Inductive Loads: Because offline transfer relays do not always phase-lock the inverter to the dying AC waveform before closing, a sudden phase jump across a running compressor or transformer core can trigger an instantaneous overcurrent trip on the inverter.
  • Silent Battery Depletion in Freezing Standby: A station left in pass-through mode below 0 °C (32 °F) continues passing grid power to the output while the BMS blocks charging; when an outage finally occurs, the battery is at a lower state of charge than expected.