On this page

For broader refrigeration load comparisons and system-level cooling choices, see the DC refrigeration load guide.

Conditions that change this baseline:

  • Ambient temperature and cabinet airflow: Moving from a 68°F (20°C) cabin to a 95°F (35°C) enclosed galley roughly doubles compressor duty cycle from ~30% to ~60%, pushing daily energy from ~350 Wh to ~750 Wh.
  • 12V vs. 24V supply: Power (W) and daily energy (Wh) stay nearly identical, but 24V halves the running and startup currents, cutting cable voltage-drop losses by a factor of four for the same wire gauge.
  • 48V battery banks: A 48V nominal system (51.2V LiFePO4, up to 58.4V absorb) cannot power a 12V/24V fridge directly and requires a dedicated 48V-to-12V or 48V-to-24V DC-DC buck converter sized for startup surge.

Will a 100Ah Battery Run a Camper Fridge for Two Nights?

A 100 Ah 12.8 V LiFePO₄ battery with 72 Ah available for the trip (100 Ah × 72% net usable budget, e.g., 90% DoD with 20% reserve) covers the 68 Ah two-night budget below with only 4 Ah of margin. Whether your own battery lasts two nights without recharging depends primarily on how often the compressor cycles.

Start With the Compressor Duty Cycle (25% vs. 40%)

Suppose a 12 V fridge draws 4 A (51.2 W at 12.8 V) while running, paired with a 1 A (12.8 W) vent fan for 8 h/day and 0.5 A (6.4 W) cabin lights for 4 h/day over 48 hours with no solar or alternator recharge:

Load Component (Illustrative) 25% Fridge Duty Cycle 40% Fridge Duty Cycle
12 V compressor fridge (4 A running, 24 h window) 4 A × 24 h × 0.25 = 24.0 Ah/day 4 A × 24 h × 0.40 = 38.4 Ah/day
Cabin fan (1 A × 8 h/day) 8.0 Ah/day 8.0 Ah/day
Cabin lights (0.5 A × 4 h/day) 2.0 Ah/day 2.0 Ah/day
Daily total 34.0 Ah/day (435.2 Wh/day) 48.4 Ah/day (619.5 Wh/day)
Two-night total (48 h, no recharge) 68.0 Ah 96.8 Ah
Runtime on 72 Ah usable budget (100 Ah × 72% at 25 °C, K_temp = 1.0) 2.12 days (50.8 h) — passes (4 Ah margin) 1.49 days (35.7 h) — short by 24.8 Ah
Runtime at 10 °C (50 °F) calculator default (K_temp = 1.05) 2.02 days (48.4 h) 1.42 days (34.0 h)

Build a Two-Night Camper Load Budget

When entering a net usable capacity percentage that already excludes your desired reserve (such as 72% above, before cold-temperature derating), enter 72% directly in Existing battery runtime mode and set the ambient temperature to 25 °C (77 °F) for the reference result above—or keep 10 °C (50 °F) (or colder) to include the K_temp cold-discharge allowance. Do not apply a reserve percentage twice. Substitute measured daily Ah from a battery shunt whenever available, and confirm the fridge can start cleanly at the voltage delivered to its rear terminals.


Core Electrical Specifications and Ambient Duty Cycle

Check the compressor module nameplate (often on the rear condenser housing or inside the fresh-food liner) for exact steady-state amps, locked-rotor/startup current, and low-voltage disconnect (LVD) thresholds. The table below uses illustrative mid-range values (50 W average running power) to show how ambient heat drives daily consumption.

Operating Condition Ambient Temp Illustrative Duty Cycle Running Power 12V Startup Pulse 24V Startup Pulse Daily Energy 12.8V LiFePO4 Ah/Day 25.6V LiFePO4 Ah/Day
Cool cabin, open condenser airflow 68°F (20°C) ~30% (7.2 h/day) 35–65 W 5–8 A 2.5–4 A ~350–400 Wh 27–31 Ah 14–16 Ah
Moderate cabin, standard cutout 77°F (25°C) ~40% (9.6 h/day) 35–65 W 5–8 A 2.5–4 A ~480–550 Wh 38–43 Ah 19–21 Ah
Hot vehicle/galley or tight recess 95°F (35°C) ~60% (14.4 h/day) 35–65 W 5–8 A 2.5–4 A ~700–750 Wh 55–59 Ah 27–29 Ah

Note: Upright front-opening fridges lose cold air faster on door openings than top-opening chest or drawer units, pushing them toward the upper end of the daily Wh range in warm climates.


Battery, PV, DC-DC Converter, and Portable Station Feasibility

Battery Bank Sizing (12V and 24V Nominal)

Size usable capacity against your worst-case hot-weather daily draw (750 Wh/day) and desired days of autonomy without solar or alternator recharge:

Required_Nameplate_Wh = (Daily_Wh * Autonomy_Days) / Usable_DoD
Required_Ah = Required_Nameplate_Wh / Nominal_Voltage
  • LiFePO4 (12.8V / 25.6V nominal, 85% default usable DoD):
    • 1 day autonomy (350–750 Wh/day): 412–882 Wh nameplate (32–69 Ah at 12.8V, or 16–34 Ah at 25.6V).
    • 2 days autonomy (700–1,500 Wh): 824–1,765 Wh nameplate (64–138 Ah at 12.8V, or 32–69 Ah at 25.6V).
  • AGM / Lead-Acid (12.0V / 24.0V nominal, 50% usable DoD):
    • 1 day autonomy (350–750 Wh/day): 700–1,500 Wh nameplate (58–125 Ah at 12.0V, or 29–63 Ah at 24.0V).
    • 2 days autonomy (700–1,500 Wh): 1,400–3,000 Wh nameplate (117–250 Ah at 12.0V, or 58–125 Ah at 24.0V).

Cold-charging check: If the battery bank sits in an unheated compartment, flag charging at <= +5°C (41°F) to verify the BMS minimum charge temperature (some commercial packs lock out at +5°C), and hard-block charging at <= 0°C (32°F) unless the battery is self-heated.

Indicative Solar (PV) Array Sizing

PV_Watts = Daily_Wh / (Peak_Sun_Hours * System_Derate)

Using an illustrative 0.75 overall system derate (MPPT efficiency, wire loss, module temperature, and tilt):

  • Summer / high sun (4.5 peak sun hours): 350 to 750 Wh/day requires 105 to 225 W of PV (practically a 150–250 W panel).
  • Shoulder season / overcast (2.5 peak sun hours): 350 to 750 Wh/day requires 190 to 400 W of PV.

Verify on the MPPT controller manual that array cold Voc stays below controller Vmax (and <= 150V DC overall), parallel Isc stays within controller Isc_max, and hot Vmp stays inside the controller startup/running voltage window.

48V-to-12V/24V DC-DC Converter Sizing

On a 48V nominal bank (51.2V LiFePO4, up to 58.4V absorb):

  • Input rating: Must accept up to at least 60V DC so 58.4V absorb charging does not trip over-voltage protection.
  • Output rating: Do not size solely for the 35–65 W running load. A 5–8 A 12V startup pulse (65–100 W, or higher if compressor head pressure is high) can trigger current-foldback or hiccup mode on an undersized 5 A converter. Use a converter rated for at least 10 to 15 A continuous at 12V (120–180 W) or 8 to 10 A continuous at 24V.
  • Output voltage: Prefer a converter that outputs 13.2–13.8V (for 12V fridges) or 26.4–27.6V (for 24V fridges) so the fridge does not interpret a flat 12.0V output as a depleted AGM battery.
  • Overcurrent protection on the 48V side: Use a fuse or breaker rated >= 60V DC (never a 32V automotive fuse or a 58V-rated terminal fuse on a 58.4V bus).

Portable Power Station 12V Port Feasibility

Running a built-in DC fridge from a portable power station is feasible only when all three limits are verified:

  1. 12V DC port current limit and regulation: Do not assume a universal 120 W car-socket limit. Check the station's exact DC port rating (some are 8 A / 96 W, others 10 A / 120 W, and Anderson/XT60 DC ports may allow 15–30 A). An 8 A startup pulse can trip an 8 A socket or overheat a spring-loaded cigarette-lighter plug. Use a regulated 12V output (12.8–13.6V) with a locking connector rather than an unregulated socket that sags below the fridge's LVD.
  2. DC conversion loss and idle tare draw: Enabling the DC output rail on a portable station typically adds 5 to 15 W of continuous idle tare draw (120 to 360 Wh/day) on top of 8–15% DC-DC conversion loss.
  3. Net usable Wh:
    Net_Fridge_Wh = (Station_Wh * 0.88) - (DC_Tare_W * 24)
    
    For example, a 500 Wh station with 88% DC efficiency and 8 W DC tare delivers (500 * 0.88) - (8 * 24) = 440 - 192 = 248 Wh/day to the fridge—less than one full day even in cool weather. A 1,000 Wh+ station is typically needed for 24-hour autonomy in warm conditions.

Job-Specific Sizing and Wiring Steps

A DC compressor fridge is a critical circuit (<= 3% voltage drop) because its built-in low-voltage disconnect measures voltage at the fridge terminals during the 5–8 A startup pulse.

  1. Confirm nameplate ratings: Record operating voltage (12V, 24V, or auto-sensing 12/24V), running amps, startup current, and factory LVD setting (commonly 10.4–11.5V for 12V, or 21.0–23.0V for 24V).
  2. Measure round-trip cable length: Multiply the one-way distance from the distribution bus (or DC-DC converter) to the fridge by 2.
    L_round_trip_m = 2 * L_one_way_ft * 0.3048
    
  3. Calculate minimum copper cross-section for <= 3% voltage drop: Use 75°C copper resistivity (0.02097 ohm·mm²/m) and the startup pulse current (I_pulse, e.g., 8 A at 12V).
    V_drop_max = Nominal_V * 0.03
    A_min_mm2 = (I_pulse * L_round_trip_m * 0.02097) / V_drop_max
    
    Illustrative 12V example (15 ft / 4.57 m one-way, 30 ft / 9.14 m round-trip, 8 A pulse, 0.384 V max drop): A_min_mm2 = (8 * 9.14 * 0.02097) / 0.384 = 3.99 mm². 12 AWG (3.31 mm²) drops 0.463 V (3.6%, fails <= 3%); 10 AWG (5.26 mm²) drops 0.292 V (2.28%, passes).
  4. Verify ampacity and cable type: Size by the larger of voltage drop and 1.25 * I_continuous, honoring 75°C terminal temperature limits. Use marine/automotive-grade tinned or bare copper (UL 1426 / ABYC), avoiding undersized SAE J1128 thin-wall insulation estimates and never using copper-clad aluminum (CCA).
  5. Select the branch fuse:
    • Fuse rating <= cable ampacity, and >= 1.25 * I_continuous while tolerating the 5–8 A startup pulse (typically 15 A for a 12V fridge on 10 AWG or 12 AWG, or check the manufacturer's specified fuse).
    • Verify fuse max voltage >= max charging voltage (32V-rated fuses cover 12V/24V systems; >= 60V DC fuses are required on a 48V converter feed).
    • Verify fuse AIC >= prospective fault current at the battery/bus.
  6. Build cabinet ventilation: Leave the manufacturer-specified rear/top clearance (typically 2 in / 50 mm minimum) and provide a lower cool-air intake and upper warm-air exhaust so condenser heat does not recirculate.

Sign-Off Criteria

  • Terminal voltage under startup pulse: Measured directly at the fridge's rear DC input terminals during compressor start, voltage remains within 3% of bus voltage and well above the fridge's LVD threshold.
  • No short-cycling: Compressor starts cleanly on the first attempt and runs steady-state without clicking off after 1–3 seconds.
  • Fuse and terminal thermal check: After 30 minutes of continuous running in warm ambient air, fuse holder, inline connectors, and converter terminals remain cool to the touch with no voltage drop across crimps.
  • 48V / Portable checks (if used): 48V DC-DC converter input is fused for >= 60V DC and holds output >= 13.0V (12V) or >= 26.0V (24V) during startup; portable station DC port does not trip or show excessive voltage sag during compressor start.

Real Failure Modes

  • False LVD shutdowns from undersized wire or poor crimps: The fridge runs briefly or clicks every few minutes while the battery monitor still reads 70–80% SoC. Voltage drop across long 14–16 AWG runs or loose blade connectors pulls terminal voltage below 11.0V during the 5–8 A startup pulse.
  • Runaway duty cycle from trapped condenser heat: Installing a built-in upright or drawer fridge flush in a sealed cabinet without an exhaust path forces the condenser to ingest hot air, pushing duty cycle toward 80–100% and doubling daily Wh.
  • 48V DC-DC converter hiccup on compressor start: A 5 A (60 W) 48V-to-12V converter meets the 50 W running average but enters overcurrent shutdown during the 8 A startup surge, leaving the fridge unpowered.
  • Cigarette-lighter plug melt or trip on portable stations: Spring-loaded 12V car plugs have high contact resistance; continuous 4–5 A draw plus 8 A startup pulses heat the center pin, trip internal thermal fuses, or cause voltage sag that triggers the fridge LVD.
  • 58V-rated fuses on a 48V LiFePO4 bank: Using a 58V-rated terminal fuse on the 48V feed to a DC-DC converter violates the fuse voltage rating when the LiFePO4 bank charges to 58.4V.

Sources and Verification

  • Blue Sea Systems — Wire Sizing & Circuit Protection (#529 / #98) — 3% critical circuit voltage-drop baseline and overcurrent protection coordination.
  • Victron Energy — Wiring Unlimited — Battery usable capacity, DC voltage drop, and fuse coordination for 12 V / 24 V / 48 V systems.
  • Equipment-specific values: Running current, compressor startup pulse, low-voltage disconnect (LVD) threshold, and ambient-temperature duty cycle vary by fridge model; always verify the appliance installation manual and measure daily Ah with a battery shunt when available.