On this page

Use LPG mode whenever running off a house battery or portable power station. Reserve 120V/60 Hz (North America) or 230V/50 Hz (UK/AU) AC mode for shore power or generator operation, and restrict the 12V DC heating element (present on three-way models only) to active engine/alternator charging via an ignition-switched or voltage-sensing relay. For 12V/24V compressor fridges that run directly from batteries without gas, see the refrigeration loads overview.

Mode Specifications and Duty Cycles

Two-way absorption fridges support AC and LPG only; three-way models add a 12V DC resistive heating element for road transit. Because absorption units use resistive heaters rather than a motor-driven compressor, they have no inductive startup surge (1.0x steady-state current).

Operating Mode Typical Power (W) Line Current Duty Cycle Daily Energy (Wh/day) Primary Supply Source
12V DC Heater (3-way only) 120–210 W 10.0–17.5 A at 12.0 V (9.4–16.4 A at 12.8 V) ~100% while driving (often un-thermostated) 2,880–5,040 Wh (if run 24 h) Tow-vehicle/RV alternator (>30 A spare capacity)
120V/60 Hz AC Heater 250–380 W 2.1–3.2 A AC 50–80% (ambient dependent) 3,000–7,300 Wh AC Shore power or generator
230V/50 Hz AC Heater (UK/AU) 250–380 W 1.1–1.7 A AC 50–80% (ambient dependent) 3,000–7,300 Wh AC Shore power or generator
LPG Mode (12V control + igniter) 4–15 W steady (10–25 W ignition spike) 0.3–1.25 A at 12.0 V 100% board / intermittent gas valve & fan 96–360 Wh DC 12V house battery or regulated 12V DC port

Check the fridge nameplate inside the fresh-food compartment for exact wattage; some 12V elements are rated at 13.5 V or 14.0 V, which slightly reduces wattage at 12.0 V.

Battery, Inverter, and Portable Power Station Feasibility

House Battery Runtime Comparison

Illustrative comparison using a 12.8 V 100 Ah LiFePO4 battery (1,280 Wh nominal; 1,088 Wh usable at 85% default DoD) and a 12.0 V 100 Ah AGM battery (1,200 Wh nominal; 600 Wh usable at 50% DoD):

  • LPG Mode (assuming 8 W average / 192 Wh/day; 15 W max with cabinet fan / 360 Wh/day):
    • 100 Ah LiFePO4: 3.0 to 5.7 days
    • 100 Ah AGM: 1.7 to 3.1 days
  • 12V DC Heater (assuming 180 W / 15.0 A at 12.0 V, 100% duty cycle):
    • 100 Ah LiFePO4: 6.0 hours (1,088 Wh / 180 W)
    • 100 Ah AGM: 3.3 hours (600 Wh / 180 W)
  • AC Heater via 12V Inverter (assuming 325 W AC element, 65% duty cycle, 85% inverter efficiency, 15 W inverter idle tare):
    • Active DC draw: 325 W / 0.85 + 15 W = 397 W (~33 A at 12.0 V)
    • Daily DC energy: (325 W * 24 h * 0.65) / 0.85 + (15 W * 24 h) = 6,325 Wh/day
    • Worst-case inverter DC current at low-voltage cutoff (V_min = 10.5 V, 380 W element, 85% efficiency): I_dc = 380 W / (10.5 V * 0.85) = 42.6 A
    • 100 Ah LiFePO4 runtime: ~2.7 hours of active heating (~4.2 hours wall-clock before cutoff).

Portable Power Station Feasibility

  • 12V DC Element via Car Socket: Not feasible for most units. Standard 12V cigarette-lighter ports are typically rated 10 A (120 W) to 15 A (180 W) max, though limits vary by station. Running a 150–210 W continuous load through a barrel/car plug overheats the plug spring and trips port overcurrent protection.
  • AC Element via Inverter Output: A 500 W+ continuous inverter easily handles the 250–380 W resistive load (no surge), but a 1,000–2,000 Wh power station still depletes in 2.5 to 5.5 hours once 15% conversion loss and 10–25 W idle tare are included.
  • LPG Mode via DC Output: Fully feasible. A 500 Wh power station runs LPG control power for 1.5 to 4 days if the 12V DC port does not auto-sleep below 5–10 W.

12V DC Wiring, Isolation, and Protection

Most three-way fridges separate the high-current 12V heater feed from the low-current 12V control/LPG feed. Never bridge the control board feed off an undersized or voltage-dropped heater wire.

Wire Sizing (75°C Copper, Round-Trip Method)

Because resistive heating power drops with the square of voltage (P = V^2 / R), a 10% voltage drop reduces heating output by 19%. Target <=3% voltage drop on the 12V heater circuit (treat <=10% only as an absolute ceiling for non-critical circuits).

Using 75°C copper resistivity (0.02097 ohm·mm²/m):

A_min (mm²) = (I_dc * L_round_trip_m * 0.02097) / V_drop_max

Worked example (illustrative 180 W element, 15.0 A at 12.0 V, 20 ft / 6.1 m one-way = 40 ft / 12.19 m round-trip):

  1. Continuous ampacity check (>= 1.25x for loads >= 3 hours): 15.0 A * 1.25 = 18.75 A.
  2. Voltage drop check at <= 3% (0.36 V max drop at 12.0 V): A_min = (15.0 * 12.19 * 0.02097) / 0.36 = 10.65 mm²
  3. Conductor selection:
    • 8 AWG (8.37 mm²) yields 0.458 V drop (3.82%)—acceptable only on shorter runs (<= 15 ft one-way).
    • 6 AWG (13.3 mm²) or 16 mm² metric yields 0.288 V drop (2.40%)—meets <= 3% and handles 75°C terminal limits cleanly.
  4. Cable traps to avoid: Do not use Copper-Clad Aluminum (CCA) or thin-wall SAE J1128 GPT automotive wire sized purely by 105°C ampacity; follow 75°C terminal ratings and pure copper cross-section.

Overcurrent Protection and Alternator Isolation

  • Heater Circuit Fuse: Size at >= 1.25x continuous current (20 A or 25 A for a 15 A load), strictly <= cable ampacity. Verify fuse max voltage >= max charging voltage (e.g., >= 14.6 V for 12.8 V LiFePO4; standard 32 V or 58 V automotive/marine fuses qualify) and AIC >= battery/alternator prospective fault current.
  • Control Board Fuse: Typically 3 A to 5 A on a dedicated 14–16 AWG (2.08–1.31 mm²) feed from the house battery bus so the fridge stays lit on LPG when the engine is off.
  • Engine-Off Isolation: Feed the 12V heater through a 40 A+ continuous-duty relay triggered by alternator D+, ignition ACC, or a voltage-sensing relay (VSR) set to close above 13.3 V and open below 12.7 V (adjust higher for LiFePO4 resting voltage of 13.3–13.4 V so the fridge does not stay on after engine shutdown).

Installation Verification and Sign-Off

  1. Nameplate check: Confirm exact 12V DC and 120V/230V AC wattages and whether the model is 2-way or 3-way.
  2. Loaded terminal voltage: With the engine running and 12V DC mode active, measure voltage directly at the fridge rear 12V heater terminal block.
    • Pass: >= 12.6 V under full heater load (<= 3% drop from alternator/distribution bus).
  3. Engine-off cutoff: Shut off the engine and confirm 12V heater terminal voltage drops to 0 V within 5–30 seconds (depending on VSR delay).
  4. Control feed check: Switch to LPG mode with engine off and verify 12V control terminal stays energized (12.0–13.6 V) and gas valve holds open.

Common Failure Modes

  • Dead Battery from Un-Isolated 12V Heater: Leaving 12V mode wired to a constant-hot bus drains a 100 Ah AGM to 50% DoD in ~3.3 hours and trips a 100 Ah LiFePO4 BMS in ~6 hours.
  • Warm Fridge in Transit (Tow-Vehicle 7-Pin Drop): Factory 7-pin trailer pin-4 auxiliary wires (often 10–12 AWG through a long chassis run) commonly drop 1.5–2.5 V under a 15 A load. At 10.5 V, a 12V heater produces only ~76% of its rated heat, stalling the ammonia boiler. Use a dedicated 6–8 AWG Anderson/high-current trailer feed or run LPG in transit where legally permitted.
  • Auto-Mode Draining Inverter Bank: Leaving the fridge in Auto while connected to an inverter causes the control board to prioritize 120V/230V AC over LPG, draining the battery at ~400 W DC instead of 8 W.
  • LPG Shutdown at Low-Temperature or BMS Cutoff: Even with a full propane tank, LPG mode stops cooling immediately if the 12V house battery hits low-voltage cutoff or if a LiFePO4 battery is depleted after cold-charging lockout (<= 0°C / 32°F hard block unless self-heated; verify BMS minimum charge limit at <= +5°C / 41°F).