On this page
Connect the transponder directly to a regulated 12 V or 24 V DC navigation bus (or through an isolated 48 V-to-12 V / 24 V DC-DC converter on a 48 V bank). Do not power a standalone AIS through an AC inverter, and do not share an unbuffered starter circuit that sags below 9.6 V during engine cranking.
Conditions that change the power design:
- Transponder class: Class B (2 W or 5 W RF) units typically draw 2 W to 5 W continuous and 1.5 A to 3.5 A peak at 12 V during transmit bursts. Class A (12.5 W RF) units draw higher continuous standby power and larger transmit bursts (verify exact ratings on the equipment nameplate).
- System voltage: Most marine AIS transponders accept 9.6 V to 31.2 V DC (12 V or 24 V nominal). A 51.2 V LiFePO4 bank (up to 58.4 V absorb) exceeds the input limit and requires a step-down DC-DC converter.
- 24-hour energy vs. burst stability: Daily energy demand is small (~50 Wh to 126 Wh per 24 hours), so wire sizing and terminal integrity are governed by the <=3% voltage-drop limit during millisecond transmit pulses rather than continuous ampacity.
For broader vessel load planning, see Marine Deck & Navigation Loads.
Continuous Draw, TDMA Transmit Bursts, and Battery Sizing
Marine AIS transponders operate on Time Division Multiple Access (TDMA) slots of approximately 26.67 ms. While the receiver and integrated GPS/GNSS module run continuously, the transmitter fires only during assigned reporting slots (typically every 5 s to 30 s depending on vessel speed, or up to every 2 s to 3 s during maneuvers).
| Operating Mode | Illustrative Power (12 V / 24 V) | Current at 12.8 V (LiFePO4) | Current at 25.6 V (LiFePO4) | Duty Cycle / Duration | Nameplate Check |
|---|---|---|---|---|---|
| Receive standby + integrated GNSS | 2.0 W to 5.0 W | 0.16 A to 0.39 A | 0.08 A to 0.20 A | Continuous (99%+) | Verify continuous draw with Wi-Fi / NMEA 2000 enabled |
| Class B TDMA transmit burst (2 W / 5 W RF) | 18 W to 42 W DC input | 1.4 A to 3.3 A | 0.7 A to 1.6 A | ~26.7 ms every 2 s to 30 s | Check peak TX current and fuse curve |
| Class A TDMA transmit burst (12.5 W RF) | 45 W to 75 W DC input | 3.5 A to 5.9 A (if 12 V supported) | 1.8 A to 2.9 A | ~26.7 ms every 2 s to 10 s | Many Class A units require 24 V DC only |
| Cold-start GNSS / internal Wi-Fi active | +0.5 W to +1.5 W | +0.04 A to +0.12 A | +0.02 A to +0.06 A | Startup or continuous if Wi-Fi on | Confirm whether NMEA 2000 bus draws extra LEN |
24-Hour Energy and Battery Capacity Math
Even with frequent transmit slots, the average power added by TDMA bursts is minor:
Illustrative Class B Burst Average Power (assuming 36 W DC input, 26.7 ms burst every 5 s):
Burst duty cycle = 0.0267 s / 5.0 s = 0.00534 (0.53%)
Average TX power = 36 W * 0.00534 = 0.19 W
24-hour TX energy = 0.19 W * 24 h = 4.6 Wh/day
Combined with 2.0 W to 5.0 W continuous receive standby (48 Wh to 120 Wh/day), total daily energy is ~50 Wh to 126 Wh/day.
- 12.8 V LiFePO4 bank (85% usable DoD):
126 Wh / (12.8 V * 0.85) = 11.6 Ah/day - 12.0 V AGM / lead-acid bank (50% usable DoD):
126 Wh / (12.0 V * 0.50) = 21.0 Ah/day - 25.6 V LiFePO4 bank (85% usable DoD):
126 Wh / (25.6 V * 0.85) = 5.8 Ah/day
If the AIS shares a LiFePO4 house bank in cold climates, flag charging temperatures at or below +5°C (41°F) to verify the battery BMS minimum charge threshold (some commercial packs lock out at +5°C), and hard-block charging at or below 0°C (32°F) unless the battery is self-heated.
Battery, Inverter, and Portable Station Feasibility
| Supply Source | Feasibility | Key Engineering Constraints |
|---|---|---|
| 12 V / 24 V DC House or Nav Bank | Recommended | Lowest loss; keep round-trip voltage drop <=3% at peak TX burst current. Isolate from starter-crank sag. |
| 48 V DC Bank (51.2 V LiFePO4) | Feasible via DC-DC Converter | Direct connection to 51.2 V nominal (56.8 V to 58.4 V absorb) will destroy 12/24 V AIS electronics. Use an isolated 48 V-to-12 V or 48 V-to-24 V converter. |
| AC Inverter (120 V/60 Hz NA or 230 V/50 Hz UK/AU) | Not Recommended | Inverter idle tare draw (typically 10 W to 25 W, or 240 Wh to 600 Wh/day) consumes 2x to 10x more energy than the AIS itself and adds unnecessary conversion failure points. |
| Portable Power Station (12 V Regulated Port) | Conditional (Backup Only) | Verify 12 V port continuous/peak current rating (do not assume a universal 120 W car-socket limit), factor ~10% to 15% DC-DC loss plus BMS tare draw into usable Wh, and confirm the port does not auto-shutoff at 2 W to 5 W standby draw. |
Installation and Wire-Sizing Steps
Verify Nameplate Ratings and Bus Voltage Window Check the AIS manual for minimum operating voltage (commonly 9.6 V DC), maximum operating voltage (commonly 31.2 V DC), peak transmit current, and whether the NMEA 2000 port is galvanically isolated from the main DC power input.
Size Conductors for <=3% Critical Circuit Voltage Drop AIS transponders are critical navigation loads and must stay within a 3% maximum voltage drop at peak transmit current using round-trip wire length (
2 x one-way length) and 75°C copper resistivity (0.02097 ohm·mm²/m).Min_Area_mm2 = (I_peak * 2 * L_oneway_m * 0.02097) / (V_nominal * 0.03)Illustrative example (12 V system, 15 ft / 4.57 m one-way run, 3.5 A peak TX burst):
- Round-trip length:
2 * 4.57 m = 9.14 m(30 ft) - Maximum allowed drop:
12.0 V * 0.03 = 0.36 V - Minimum copper area:
(3.5 A * 9.14 m * 0.02097) / 0.36 V = 1.86 mm² - Select 14 AWG (2.08 mm²) marine-grade tinned copper (75°C or 105°C rated insulation). Even though continuous current is under 0.5 A, 14 AWG prevents burst brownout.
- Always size by the larger of voltage drop and derated ampacity (
>= 1.25 x continuous currentfor >=3 h loads), honor terminal temperature limits (often 75°C), and avoid un-tinned SAE J1128 automotive wire or copper-clad aluminum (CCA) cable.
- Round-trip length:
Install Properly Rated Overcurrent Protection Place the fuse or circuit breaker as close as practical to the positive bus or distribution panel:
- Fuse current rating: Must be
<= cable ampacity,>= 1.25 x continuous current, and sized per the manufacturer's manual (commonly 3 A to 5 A) so its time-current curve tolerates 26.7 ms TX bursts without nuisance opening. - Fuse voltage rating: Must meet or exceed the maximum charging voltage (
>= 16 Vfor 12 V,>= 32 Vfor 24 V). On a 48 V LiFePO4 upstream feed (up to 58.4 V absorb), use fuses rated >= 60 V DC; standard 58 V-rated terminal fuses are exceeded at 58.4 V. - Interrupt rating (AIC): Confirm prospective fault current from the battery bank does not exceed the fuse's AIC at operating voltage.
- Fuse current rating: Must be
Check Grounding and RF Separation Route DC power leads away from the VHF/AIS coaxial feedline and verify any dedicated RF ground terminal (if present on the chassis) follows the vessel's bonding scheme without creating DC ground loops.
Commissioning Sign-Off Criteria
- Burst voltage stability: Measured DC voltage at the transponder input plug during an active TDMA transmit burst drops <=3% from the distribution bus and remains >= 10.5 V (12 V bus) or >= 21.0 V (24 V bus).
- Crank / transient immunity: Starting the main engine or engaging high-draw deck loads (windlass, bow thruster) does not reboot the AIS or drop its GNSS fix.
- Protection compliance: Fuse ampacity is <= conductor ampacity, fuse voltage rating is >= max charging voltage, and prospective fault current is <= fuse AIC.
- Portable backup verification (if used): The portable power station 12 V DC port stays active under 2 W to 5 W continuous standby for at least 2 hours without triggering low-load auto-shutoff.
Real Failure Modes
- Silent TX Burst Brownout: Undersized wire (such as 18 AWG / 0.82 mm² or 20 AWG / 0.52 mm² over a long helm-to-battery run), corroded inline glass fuse holders, or CCA wire causes a >0.5 V to 1.5 V sag during the 26.7 ms transmit pulse. The unit resets mid-packet, loses GNSS lock for 30 to 60 seconds, and stops transmitting without blowing the fuse.
- Engine-Crank Voltage Sag: Tapping the AIS directly off a starter battery without isolation or a DC-DC stabilizer pulls the AIS below its ~9.6 V cutoff during cranking, interrupting collision-avoidance tracking when leaving an anchorage or dock.
- Portable Station Auto-Shutoff: Many portable power stations turn off their regulated 12 V DC output after 1 to 4 hours when draw stays below 5 W to 10 W, silently shutting down AIS overnight.
- 48 V Bus Overvoltage Failure: Wiring a 12/24 V-rated AIS directly to a 51.2 V LiFePO4 bank (up to 58.4 V absorb) permanently damages the internal power supply stage.
- Inverter Tare Drain: Running a 3 W AIS through a 120 V/60 Hz or 230 V/50 Hz inverter adds 10 W to 25 W of continuous idle tare loss, depleting a small battery bank several times faster than the transponder itself.
Part of Marine Deck and Navigation Loads