For 12V, 24V, and 48V off-grid, RV, marine, cabin, and portable DC systems, size your solar array using the worst-month (design-month) PSH for your actual panel tilt—never total daylight hours and never the annual average if you operate in winter. Multiply nameplate Standard Test Conditions (STC) watts by PSH and a real-world system derate factor (typically 0.75 to 0.85) to estimate daily harvest.

This figure shifts sharply with three site conditions:

  • Season and latitude: Summer sites often deliver 5.0–6.5 PSH, while winter months at mid-to-high latitudes drop to 1.0–2.5 PSH.
  • Panel tilt vs. flat mounting: RV and marine roofs mounted flat (0° tilt) capture roughly 25%–45% less winter insolation than a cabin array tilted to latitude.
  • Horizon shading and weather: Trees, roof racks, vents, marine rigging, and coastal fog reduce effective PSH below regional weather-station tables.

For related DC terms and definitions, see the DC Power Specs Glossary.

Core Specifications and Accounting Formulas

Solar modules are rated under STC (1,000 W/m2 irradiance, 25°C / 77°F cell temperature, 1.5 air mass). PSH converts a full day's bell-shaped irradiance curve into an equivalent block of hours at that 1,000 W/m2 STC benchmark.

1 PSH = 1,000 Wh/m2 = 1.0 kWh/m2

Daily Array Yield (Wh) = Array_STC (W) x PSH (h) x System_Derate

Required Array_STC (W) = Daily_Load (Wh) / (PSH (h) x System_Derate)

Daily Battery Charge (Ah) = Daily Array Yield (Wh) / Nominal_Bus_V (V)
Parameter Typical Value / Range Engineering Basis
Standard irradiance reference 1,000 W/m2 PV module nameplate STC rating
Energy equivalent per 1 PSH 1,000 Wh/m2 (1 kWh/m2) Integrated daily solar insolation
Real-world MPPT system derate 0.75–0.85 (0.80 baseline) Accounts for hot cells (>25°C / 77°F), MPPT conversion, wiring drop (<=3%), and soiling
PWM controller derate 0.55–0.70 Fixed voltage clamping loses panel headroom above battery voltage
DC bus voltage ceiling <=60V DC 12V (12.0V/12.8V), 24V (24.0V/25.6V), 48V (48.0V/51.2V) nominal
PV array open-circuit limit Cold Voc <=150V DC Disconnect and touch-safety controls required above 60V DC

Illustrative Daily Yield by System Voltage

The table below shows illustrative daily harvest for a 400W STC array using an assumed 0.80 system derate (400 W x 0.80 = 320 W effective). Actual output depends on nameplate ratings, ambient cell temperature, and controller efficiency.

Design PSH (h/day) Effective Daily Harvest (Wh) 12V LiFePO4 (12.8V nom) Ah 12V AGM (12.0V nom) Ah 24V LiFePO4 (25.6V nom) Ah 48V LiFePO4 (51.2V nom) Ah
1.5 PSH (winter / overcast) 480 Wh 37.5 Ah 40.0 Ah 18.8 Ah 9.4 Ah
3.0 PSH (shoulder season) 960 Wh 75.0 Ah 80.0 Ah 37.5 Ah 18.8 Ah
4.5 PSH (clear spring/fall) 1,440 Wh 112.5 Ah 120.0 Ah 56.3 Ah 28.1 Ah
6.0 PSH (peak summer) 1,920 Wh 150.0 Ah 160.0 Ah 75.0 Ah 37.5 Ah

Step-by-Step PSH Yield Calculation

  1. Pull site PSH for the exact mount angle and worst operating month. Use a solar insolation database (such as NREL PVWatts or equivalent regional meteorological data) set to your panel tilt: 0° for flat RV/marine roofs, or latitude-matched / winter-steep tilt for cabins. Select the lowest PSH month in which the system must remain autonomous.
  2. Verify PV nameplate and controller voltage limits. Check the module nameplate for Pmax (STC watts), Voc, and Vmp, and the charge controller manual for MPPT_Vmax and startup/running voltage windows. Confirm that cold-weather array Voc < MPPT_Vmax and strictly <=150V DC, and that hot-weather Vmp stays above the controller's minimum tracking voltage.
  3. Apply a conservative derate factor. Start with 0.80 for an MPPT array with clean, unshaded panels and <=3% PV-to-controller wiring voltage drop. Drop the derate to 0.65–0.75 if panels run hot on an unventilated roof, sit behind partial rigging/roof-rack shade, or feed a portable power station through long, small-gauge leads.
  4. Calculate daily Wh and check against battery usable capacity. Multiply Array_STC x Design_PSH x Derate to get net Wh entering the DC bus. Confirm that daily harvest covers your daily DC and inverter Wh demand (including AC inverter idle tare draw and conversion losses) without exceeding battery usable Depth of Discharge (80%–90%, default 85% for LiFePO4; 50% for AGM/lead-acid).
  5. Account for cold-temperature charge limits. If ambient or battery compartment temperatures drop to <=+5°C (41°F), verify the battery BMS minimum charge temperature on the datasheet (some commercial packs lock out charging at +5°C). Hard-block charging at <=0°C (32°F) unless the pack has active self-heating; available PSH produces zero stored energy while charging is locked out.

Sign-Off Criteria

Before finalizing an off-grid array or DC charging budget based on PSH:

  • Design PSH matches the worst operating month and actual panel tilt (0° for flat-mounted mobile roofs).
  • Daily harvest (Array_STC x PSH x Derate) meets or exceeds daily load Wh plus inverter conversion and idle tare losses.
  • Battery bank usable capacity (85% default DoD for LiFePO4; 50% for AGM) bridges expected low-PSH multi-day weather streaks.
  • Array cold Voc stays below MPPT_Vmax and <=150V DC; battery bus stays <=60V DC (absorb 14.2–14.6V / 28.4–29.2V / 56.8–58.4V for LiFePO4).
  • Low-temperature charge protection is verified for <=+5°C (41°F) and <=0°C (32°F) operation.

Common Failure Modes

  • Treating daylight hours as PSH: Assuming 12 hours of summer daylight equals 12 PSH overestimates daily solar harvest by 2x to 3x because morning, late-afternoon, and angled sun deliver far less than 1,000 W/m2.
  • Sizing year-round cabins with annual average PSH: An annual average of 4.5 PSH hides a 1.5 PSH December, starving AGM banks of full absorption charges (accelerating sulfation) and leaving LiFePO4 banks depleted mid-winter.
  • Using tilted PSH tables for flat RV or boat roofs: Flat-mounted panels reflect more low-angle winter sunlight; applying tilted PSH data without a flat-mount correction leaves winter mobile rigs 25%–45% short on energy.
  • Ignoring thermal and wiring derates: Multiplying STC watts directly by PSH assumes 25°C (77°F) solar cells and zero controller or wire loss. Roof-mounted panels regularly reach 55°C–65°C (131°F–149°F), cutting actual power output by 12%–20% before MPPT or cable losses.
  • Assuming full PSH harvest when the battery is full or cold-locked: PSH measures available solar energy, not energy your battery can accept. Once a LiFePO4 bank reaches absorb voltage (e.g., 14.4V / 28.8V / 57.6V) by midday—or if a cold BMS blocks charging below +5°C (41°F) or 0°C (32°F)—remaining afternoon PSH is curtailed and cannot be banked.